Conceptual Reference Database for Building Envelope Research Prev
Next
Related Concept
  • experiments and testing
  • measurement: hygrothermal properties
  • measurement: moisture content
  • measurement: vapor diffusion properties, WVT



  • Related Articles
  • EDRA: Envelope Drying Rates Analysis Experiment
  • a survey: Experimental programs on wetting-drying tests of building envelope
  • Finland research project: dyring process 1999-2003
  • MEWS-NRC/IRC, Consortium for Moisture Management for Exterior Walls
  • MT: moisture transport
  • Survey of existing experimental work on wetting and drying of building envelope

  • Concept:

    experiment: hygrothermal performance

    project on wetting and drying of envelope
    Related References
    --------
    A "follow-up" study of moisture conditions and performance of moisture sensors in flat roofs provided with exterior insulation in the late seventies, by Christensen, G. and Bunch-nielsen, T., 2002
    --------
    Approach for the simulation of wetting due to rain infiltration for building envelope testing, by St-Hilaire, A., Derome, D. and Fazio, P., 2003
    EDRA for wetting-drying of cladding wall
    British Columbia building envelope research program, by Salerno, M., 2000
    --------
    Convection in highly insulated building structures, by Okland, O., 1998
    --------
    Drying capabilities of wood frame walls with wood siding, by Salonvaara, M. H., Ojanen, T., Kokko, E. and Karagiozis, A. N., 1998
    --------
    Drying of timber-framed wall structures, by Vinha, J., 2000
    --------
    Envelope Drying Rates Experiment, Final Report, by Hazleden, D., 2001
    --------
    Envelope Drying Rates Experiment, Final Report, by Hazleden, D., 2001
    --------
    Experimental setup for the study of air leakage patterns, by Desmarais, G., Derome, D., Fazio, P., 1998
    --------
    Final Report from Task 8 of MEWS Project (T8-03) - Hygrothermal Response of Exterior Wall Systems to Climate Loading: Methodology and Interpretation of Results for Stucco, EIFS, Masonry and Siding Clad Wood-Frame Walls, by Beaulieu, P., Bomberg, M., Cornick, S., Dalgliesh, A., Desmarais, G., Djebbar, R., Kumaran, K., Lacasse, M., Lackey, J. Maref, W., et al., 2002
    wood wall
    Heat and moisture transfer in wood-based wall construction: measured versus predicted, by Zarr, R. R., Burch, D. M. and Fanney, A. H., 1995
    --------
    Hygrothermal calculations and laboratory tests on timber-framed wall structures , by Kalamees, T. and Vinha, J., 2003
    --------
    Hygro-thermal performance of hollow bricks and current standards, by Bondi, P. and Stefanizzi, P., 2001
    --------
    Hygrothermal performance of insulated, sloped, wood-framed roof assemblies, by Schumacher, C. J., 2008
    --------
    Impact of added insulation on the hygrothermal performance of leaky exterior wall assemblies, by Desmarais, G., 2000
    --------
    Impact of air leakage pattern on reinsulated walls, by Desmarais, G., Derome, D., Athienitis, A. K. and Fazio, P., 1998
    --------
    Improving the drying efficiency of timber frame walls in cold climates, by using exterior insulation, by Ojanen, T., 1998
    --------
    Large scale testing of two flat roof assemblies insulated with cellulose, by Derome, D. and Fazio, P., 1998
    --------
    Measurements and simulations of natural and forced convection in loose-fill attic insulation , by Wahlgren, P., 2002
    prefabricated, lightweight, wood-based membrane-roof
    Moisture conditions of non-ventilated, wood-based, membrane-roof components, by Rode, C., Crhistensen, G. and Vesterlokke, M., 1992
    --------
    Moisture in combined concrete timber-frame walls without vapour barrier, by Stang, B. D., Nicolajsen, A. and Hansen, M. H., 2002
    --------
    Moisture occurrence in roof assemblies containing moisture storing insulation and its impact on the durability of building envelope, by Derome, D., 2000
    --------
    Moisture transport in timber-framed external wall structures in Nordic climate - laboratory tests, by Vinha, J., K?kel?, P. and Lindberg, R., 2002
    field
    Monitoring of the building envelope of a heritage house: a case study, by Sa?d, M. N. A., W. C. Brown, C. J. Shirtliffe and A. H. P. Maurenbrecher, 1999
    --------
    On the influence of cavity ventilation on moisture content in timber frame walls, by Hansen, M. H., Nicolajsen, A. and Stang, B. D., 2002
    EDRA pilot
    Stucco-clad wall drying experiment, by Lawton, M. D., Brown, W. C. and Lang, A. M., 1999
    field testing of 16 specimens
    Temperature and moisture performance of wall assemblies with fiberglass and cellulose insulation, by Rose, W. B. and McCaa, D. J., 1998
    --------
    Test method to measure the relative capacity of wall panels to evacuate moisture from their stud cavity, by Fazio, P., Mao, Q., Ge, H., Alturkistani, A. and Rao, J., 2007
    The Ontario wall drying project
    The Ontario wall drying project, by Burnett, E.F.P. and A. J. Reynolds, 1992
    --------
    Water vapour transmission in wall structures due to diffusion and convection, by Vinha, J. and Kakela, P., 2000




    CRDBER, at CBS, BCEE, ENCS, Concordia,