| Essay:Wood studs vs. steel studs"Laboratory research into the performance of steel-framed walls has been conducted in Canada by the National Research Council's Institute for Research in Construction (IRC) and in the U.S. by the National Association of Home Builders (NAHB) Research Centre and the Oak Ridge National Laboratory. The laboratory tests use a hot-box method which tests clear wall systems that are isolated from any other parts of the structure. These tests have confirmed that steel studs severely lower the effective R-value of the assembly. " - Online sourceFor more detailed analysis see Thermal Performance of Light-Frame Assemblies by CWC-Canadian Wood Council
Steel Framing Technology Development and the Steel Framing Alliance by E-283 PATH: Partnership for Advancing Technology in Housing More info of this article can be found on the web at: http://www.cwc.ca/publications/tech_bulletins/tech_bull_3/ Web Links:
|