Simulation and measurement of the stationary and transient characteristics of the hot sphere anemometer

Loomans, M. and A. Schijndel
2002
Building and Environment, 37(2): 153-163
Hot sphere anemometer; Measurement accuracy (stationary, transient); Calibration (stationary, transient); Low velocity; Indoor characteristics


Loomans, M. and A. Schijndel, (2002), "Simulation and measurement of the stationary and transient characteristics of the hot sphere anemometer", Building and Environment, 37(2): 153-163.
Abstract:
The omni-directional hot sphere anemometer, that applies a separate reference point for the temperature correction, currently is the most practical device that is used for the measurement of indoor air flows. The anemometer has been investigated, experimentally and numerically, with regard to stationary and transient aspects for application in the indoor air flow field. Significant deviations result when specific stationary restrictions and corrections are not recognised. The transient investigation shows a significant influence of the damping on the measurement signal in the frequency range that also prevails at indoor air flows. The measured turbulence intensity can be underestimated by approximately 20%. This may result in a 50% deviation of the percentage of dissatisfied (PD) as is found in the definition of draught.

This link has not been checked.Online (Concordia user only)


Related Resources:
  • This link has not been checked.ANSI-- American National Standards Institute
    "a private, non-profit organization (501(c)3) that administers and coordinates the U.S. voluntary standardization and conformity assessment system. to enhance both the global competitiveness of U.S. business and the U.S. quality of life by promoting and facilitating voluntary consensus standards and conformity assessment systems, and safeguarding their integrity."
  • Journal: Building and Environment

This publication in whole or part might be found online. Check the sources on the related article below. Or use search engines on the web.

Related Concepts


Author Information and Other Publications Notes
Loomans, M.
TNO Building and Construction Research, P.O. Box 49, 2600 AA Delft, Netherlands
  1. The measurement and simulation of indoor air flow  
Schijndel, A.
Department of Architecture, Building and Planning, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, Netherlands
  1. Estimating values for the moisture source load and buffering capacities from indoor climate measurements  



CRDBER, at CBS, BCEE, ENCS, Concordia,