Indoor particulate matter of outdoor origin: importance of size-dependent removal mechanisms

Riley, W. J., Mckone, T. E., Lai, A. C. and Nazaroff, W. W.
2002
Environ Sci Technol 2002 Apr 15;36(8):1868


Riley, W. J., Mckone, T. E., Lai, A. C. and Nazaroff, W. W., (2002), "Indoor particulate matter of outdoor origin: importance of size-dependent removal mechanisms", Environ Sci Technol 2002 Apr 15;36(8):1868.
Abstract:
Adverse human health effects have been observed to correlate with levels of outdoor particulate matter (PM), even though most human exposure to PM of outdoor origin occurs indoors. In this study, we apply a model and empirical data to explore the indoor PM levels of outdoor origin for two major building types: offices and residences. Typical ventilation rates for each building type are obtained from the literature. Published data are combined with theoretical analyses to develop representative particle penetration coefficients, deposition loss rates, and ventilation-system filter efficiencies for a broad particle size range (i.e., 0.001-10 microm). We apply archetypal outdoor number, surface area, and mass PM size distributions for both urban and rural airsheds. We also use data on mass-weighted size distributions for specific chemical constituents of PM: sulfate and elemental carbon. Predictions of the size-resolved indoor proportion of outdoor particles (IPOP) for various conditions and ambient particle distributions are then computed.The IPOP depends strongly on the ambient particle size distribution, building type and operational parameters, and PM metric. We conclude that an accurate determination of exposure to particles of ambient origin requires explicit consideration of how removal processes in buildings vary with particle size.


Related Concepts


Author Information and Other Publications Notes
Riley, W. J.
Indoor Environment Department, E.O. Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA. wjriley@lbl.gov
  1. Factors affecting the concentration of outdoor particles indoors: Existing data and data needs  
Mckone, T. E.
Indoor Environment Department, E.O. Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA. wjriley@lbl.gov
  1. Factors affecting the concentration of outdoor particles indoors: Existing data and data needs  
Lai, A. C.
http://www.ntu.edu.sg/home/mcklai/
  1. Particle deposition indoors: a review  
Nazaroff, W. W.
Lawrence Berkeley National Laboratory, Berkeley, California
  1. Modeling particle penetration through cracks in building envelopes
  2. Modeling pollutant penetration across building envelopes
  3. Nonlinear least-squares minimization applied to tracer gas decay for determining airflow rates in a two-zone building
  4. Particle deposition from turbulent flow: review of published research and its applicability to ventilation ducts in commercial buildings
  5. Particle penetration through building cracks
  6. Particle penetration through windows  