Flow and heat transfer inside a PV/T collector for building application
Zogou, O. and Stapountzis, H.
2012 Applied Energy, 91(1): 103-115
Keywords: Building integrated photovoltaics; Flow field; PV cooling; Hot wire anemometry; Flow visualization; CFD
Zogou, O. and Stapountzis, H., (2012), "Flow and heat transfer inside a PV/T collector for building application", Applied Energy, 91(1): 103-115.
Abstract: |
In certain building applications, the PV installation is extended to cover also south- or west-facing walls, taking care to circulate cooling air to the back of the panels. The cooling effect maintains a high conversion efficiency of the PV panels and the heated air may be exploited by the HVAC or service water heating system. Sizing and design of the double fa?ade system is critical to its energetic performance. In this paper, the results from flow visualization and hot wire anemometry measurements performed on the basic structural module of a double-skin photovoltaic (PV/T) fa?ade are discussed. The concept and its feasibility have been presented in a previous paper. The results of transient outdoor measurements with the testing device have been reported elsewhere. The air flow and turbulence field inside the cavity is analyzed in the present paper by means of indoor measurements with the testing device. The results are combined with CFD computations to calculate heat transfer coefficients and improve our understanding and modeling of the specific PV/T concept. |
|
|
This publication in whole or part may be found online at: here. |
Related Concepts
|
|