Data are presented for the distribution of surface temperatures on the warm-side surface of seven different insulated glazing units. Surface temperatures are measured using infrared thermography and an external referencing technique. This technique allows detailed mapping of surface temperatures that is non-intrusive. The glazings were placed between warm and cold environmental chambers that were operated at conditions corresponding to standard design conditions for winter heating. The temperatures conditions are 21.1¡ãC (70¡ãF) and -17.8¡ãC (0¡ãF) on the warm and cold sides, respectively. Film coefficients varied somewhat with average conditions of about 7.6 W/m2¡ÁK (1.34 Btu/h¡Áft2¡Á¡ãF) for the warm-side and 28.9 W/m2¡ÁK (5.1 Btu/h¡Áft2¡Á ¡ãF) for the cold-side. Surface temperature data are plotted for the vertical distribution along the centerline of the IG and for the horizontal distribution along the centerline. This paper is part of larger collaborative effort that studied the same set of glazings.
References:
AC. 1992. Operation and maintence Instructions: A1011 Precision RTD Thermometer Azonix Document F19-100257. Billerica, MA.: Azonix Corporation.
Arasteh, D.K., F. Beck, B.T. Griffith, N. Byars, and M. Acevedo-Ruiz. 1992. Using infrared thermography to study building heat transfer. ASHRAE Journal 34(10):34-38.
ASTM.1990b. ASTM C 1199, Standard test method for measuring the steady state thermal transmittance of fenestration systems using hot box methods. Annual Book of
ASTM Standards, vol. 04.06: 671-682. Philadelphia, PA: American Society for Testing Materials.
CIS. 1992. SR 80 extended area infrared radiation source operation manual. Agoura Hills, CA.: CI Systems, Inc.
de Abreu, P., Fraser, R.A., Sullivan , H.F. and Wright, J.L., 1996. A study of insulated glazing unit surface temperature profiles using two-dimensional computer simulation. accepted for ASHRAE Transactions Vol. 102, Pt. 2.
Elmahdy, H. 1996 Surface temperature measurement of insulated glass units using infrared thermography. Accepted for ASHRAE Transactions Vol. 102, Pt. 2.
Griffith, B.T. F. Beck, D. Arasteh, and D. Turler. 1995. Issues associated with the use of infrared thermography for experimental testing of insulated systems. Proceedings of the Thermal Performance of the Exterior Envelopes of Buildings VI Conference.
Atlanta, GA.:American Society of Heating, Refrigerating and Air-Conditioning Engineers.
Holman, J. P. 1986. Heat transfer. p 334 - 336. McGraw Hill.
II. 1989. Model 600L operator's manual. N. Billerica, MA.: Inframeterics, Inc.
Sullivan, H.F., Wright, J.L. and Fraser, R.A. 1996. Overview of a project to determine the surface temperatures of insulated glazing units: thermographic measurement and 2-D simulation. accepted for ASHRAE Transactions Vol. 102, Pt. 2.
Zhao, Y., D. Curcija, and W.P. Goss. 1996. Condensation resistance validation project - Detailed computer simulations using finite element methods. ASHRAE Transactions Vol. 102, Pt. 2. |