Study of penetration of outdoor fine particles into nonresidential building with multizone simulation.

Liu, X., Zhai, Z., Facciola, N. A. and Miller, S. L.
2007
ASHRAE Transactions, 113(2): 163-171


Liu, X., Zhai, Z., Facciola, N. A. and Miller, S. L., (2007), "Study of penetration of outdoor fine particles into nonresidential building with multizone simulation.", ASHRAE Transactions, 113(2): 163-171.
Abstract:
Fine particulate matter can be inhaled into and accumulate deep in human respiratory systems because of their small sizes and long air-suspending time, causing serious health concerns. It is crucial to understand fine particle indoor dispersion behavior and their relationship with outdoor particle conditions. However, sophisticated building configurations such as atrium, stairwell, and elevator space, and complicated heating, ventilating, and air-conditioning (HVAC) systems add to the complexities of identifying the indoor-outdoor correlations. Along with a field particle concentration measurement in a three-story institutional building, this paper reports a study of the feasibility and effectiveness of using a multizone simulation program to predict the penetration of outdoor fine particles into large nonresidential buildings. The study used measured indoor and outdoor fine particle concentrations and HVAC supply conditions to calibrate the simulation model. The calibrated model was then used to predict the indoor fine particle dispersions with the real outdoor weather and particle conditions. Good agreement is obtained between the simulation and experimental results. The study found that accurate specification of actual fan-driven ventilation rates is most important for achieving good simulation results when the mechanical system is on, while properly defining exterior envelope leakages is more critical when the system is off. The paper demonstrates a practical approach to conducting a multizone airflow and contaminant simulation for large buildings for which both blower door and tracer gas tests are difficult.

This link has not been checked.Online (Concordia user only)


This publication in whole or part might be found online. Check the sources on the related article below. Or use search engines on the web.

Related Concepts


Author Information and Other Publications Notes
Liu, X.
     
Zhai, Z.
  1. Application of computational fluid dynamics in building design: aspects and trends
  2. Evaluation of various turbulence models in predicting airflow and turbulence in enclosed environments by CFD: Part 1 -- summary o
  3. Experimental and numerical investigation on thermal and electrical performance of a building integrated photovoltaic¨Cthermal col
  4. Impact of determination of convective heat transfer on the coupled energy and CFD simulation for buildings
  5. On approaches to couple energy simulation and computational fluid dynamics programs
  6. Performance of coupled building energy and CFD simulations
  7. Sensitivity analysis and application guides for integrated building energy and CFD simulation  
Facciola, N. A.
     
Miller, S. L.
  1. Nonlinear least-squares minimization applied to tracer gas decay for determining airflow rates in a two-zone building
  2. Total and culturable airborne bacteria and fungi in arid region flood-damaged residences  



CRDBER, at CBS, BCEE, ENCS, Concordia,