References

  1. Scheffer, T. C. and Moses, C. S., (1993), Survey of moisture content in houses for evidence of decay susceptibility. (30-3-09)
  2. Melencion, N. and Morrell., , (2007), Performance of antisapstain compounds on kiln-dried Douglas-fir and hem-fir lumber subjected to rewetting. (30-3-09)
  3. Nofal, M. and Morris, P., (2003), Criteria for unacceptable damage on wood systems. (30-3-09)
  4. Winandy, J. and Morrell., J., (1993), Relationship between incipient decay, strength, and chemical composition of Douglas-fir heartwood. (30-3-09)
  5. Winandy, e., Curling, S. and Lebow, P.K., (2005), Controlling moisture content of wood samples using a modified soil-pan decay method. (30-3-09)
  6. Yang, D., Gignac, M. and Bisson, M., (2004), Sawmill evaluation of a bioprotectant against moulds, stain, and decay on green lumber. (30-3-09)
  7. Curling, S. F. and Murphy, R. J., (1999), The effect of artificial ageing on the durability of wood-based board materials against basidiomycete decay fungi. (30-3-09)
  8. Kartal, S. N., Ayrilmis, N. and Imamura , Y., (2007), Decay and termite resistance of plywood treated with various fire retardants. (30-3-09)
  9. Cust¨Ždio, J., Broughton, J. and Cruz, H., (2009), A review of factors influencing the durability of structural bonded timber joints. (30-3-09)
  10. Committee on Partnerships for Emerging Research Institutions, (2009), Partnerships for Emerging Research Institutions: Report of a Workshop. (30-3-09)
  11. Mortensen, L. H., Woloszyn, M., Rode, C. and Peuhkuri, R., (2007), Investigation of Microclimate by CFD Modeling of Moisture Interactions between Air and Constructions. (19-3-09)
  12. Salas, V. and Olias, E., (2009), Overview of the photovoltaic technology status and perspective in Spain . (16-3-09)
  13. Hachem, C., Fazio, P., Rao, J. and Bartlett, K., (2009), Identification and transport investigation of microbial volatile organic compounds in full-scale stud cavities. (16-3-09)
  14. Santos, G.H.D. and Mendes, N., (2009), Combined Heat, Air and Moisture (HAM) Transfer Model for Porous Building Materials. (16-3-09)
  15. Veiseh, S., Hakkaki-fard,, Kowsary, , (2009), Determination of the air/fiber conductivity of mineral wool insulations in building applications using nonlinear estimation meth. (16-3-09)
  16. Cornick, C., Dalgliesh, S. D. and Alan, W., (2009), Adapting rain data for hygrothermal models. (13-3-09)
  17. Rode, R. and Grau, K., (2008), Moisture buffering and its consequence in whole building hygrothermal modeling. (13-3-09)
  18. Judkoff, R. D. and Neymark, J. S., (1995), Building Energy Simulation Test (BESTEST) and Diagnostic Method. National Renewable Energy Laborator. (13-3-09)
  19. Cunningham, M. J., (1992), Effective penetration depth and effective resistance in moisture transfer. (13-3-09)
  20. Rode, C., Peuhkuri, R., Time, B., Svennberg, K. and Ojanen, T., (2007), Moisture buffer value of building materials. (12-3-09)
  21. Kwiatkowski, J., Woloszyn, M., Roux, J., (2009), Modelling of hysteresis influence on mass transfer in building materials. (12-3-09)
  22. Abadie, M.O. and Mendon?a, K.C., (2009), Moisture performance of building materials: From material characterization to building simulation using the Moisture Buffer Value. (12-3-09)
  23. Roels, S., Janssen, H., (2006), A comparison of the Nordtest and Japanese test methods for the moisture buffering performance of building materials. (12-3-09)
  24. Erinjeri, J. J., Witriol, N. M., Katz, M., (2009), Measurement of Return Leaks in Residential Buildings in North Louisiana. (5-3-09)
  25. Gao, J., Zhao, J.N., Gao, F.S., Zhang, X., (2009), Modeling of Indoor Thermally Stratified Flows on the Basis of Eddy Viscosity/Diffusivity Model: State of the Art Review. (5-3-09)
  26. Yoshino, H., Mitamurab T. and Hasegawa, K., (2009), Moisture buffering and effect of ventilation rate and volume rate of hygrothermal materials in a single room under steady state. (4-3-09)
  27. Wiser, R., Barbose, G. and Peterman, C., (2008), Tracking the Sun: The Installed Cost of Photovoltaics in the U.S. from 1998--2007. (23-2-09)
  28. Joel Makower and the editors of GreenBiz.com, (2009), State of Green Business 2009. (16-2-09)
  29. He, H. S., (2006), IFC-based framework for evaluating building envelope performance. (13-2-09)
  30. Tan, X., (2008), Automatic code compliance checking in designing building envelopes. (13-2-09)
  31. Candanedo, L., (2005), Characterization and modeling of unsaturated water liquid transport in softwoods. (13-2-09)
  32. Wu, Yang, (2007), Experimental study of hygrothermal properties for building materials. (13-2-09)
  33. Teasdale St-Hilaire, A, (2006), Hygrothermal performance of different wood-frame wall assemblies wetted by simulated rain infiltration. (13-2-09)
  34. Saiz-jimenez, C., (), Biodeterioration: An Overview of the State-of-the-Art and Assessment of Future Directions. (13-2-09)
  35. Johansson, P., Samuelson, I., Ekstrand-tobin, A., Mj?rnell, K., Sandberg, P. I. and Sikander, E., (2005), Microbiological growth on building materials - critical moisture levels. State of the art. (13-2-09)
  36. Janssen, H. and Roels, S., (2009), Qualitative and quantitative assessment of interior moisture buffering by enclosures. (12-2-09)
  37. Fazio, P. and Rizzo, S.J., (1979), Nonlinear elastic analysis of panelized shear sandwich walls. (6-2-09)
  38. Li, Q., Rao, J. and Fazio, P., (2009), Development of HAM tool for building envelope analysis. (2-2-09)