Conceptual Reference Database for Building Envelope Research Prev
Next

E72-98 Standard Test Methods of Conducting Strength Tests of Panels for Building Construction

ASTM
1998
American Society for Testing and Materials, Philadelphia, Pa


ASTM, (1998), E72-98 Standard Test Methods of Conducting Strength Tests of Panels for Building Construction, American Society for Testing and Materials, Philadelphia, Pa.
Abstract:
1. Scope

1.1 These test methods cover the following procedures for determining the structural properties of segments of wall, floor, and roof constructions:

Section Test Specimens 3 Loading 4 Deformation Measurements 5 Reports 6 Precision and Accuracy 7 TESTING WALLS Significance and Use 8 Compressive Load 9 Tensile Load 10 Transverse Load-Specimen Horizontal 11 Transverse Load-Specimen Vertical 12 Concentrated Load 13 Impact Load-See Test Methods E 695 and E 661 Racking Load-Evaluation of Sheathing 14 Materials on a Standard Wood Frame Racking Load-Evaluation of Sheathing 15 Materials (Wet) on a Standard Wood Frame TESTING FLOORS Significance and Use 16 Transverse Load 17 Concentrated Load 18 Impact Load-See Test Methods E 695 and E 661 TESTING ROOFS Section Significance and Use 19 Transverse Load 20 Concentrated Load 21 APPENDIX Technical Interpretation XI

1.2 Metric units are to be considered as the primary standard units.

2. Referenced Documents

E4 Practices for Force Verification of Testing Machines

E564 Practice for Static Load Test for Shear Resistance of Framed Walls for Buildings

E575 Practice for Reporting Data from Structural Tests of Building Constructions, Elements, Connections, and Assemblies

E661 Test Method for Performance of Wood and Wood-Based Floor and Roof Sheathing Under Concentrated Static and Impact Loads

E695 Test Method of Measuring Relative Resistance of Wall, Floor, and Roof Constructions to Impact Loading

E73 Practice for Static Load Testing of Truss Assemblies

Index Terms

compressive load; concentrated loads; deformation; floors; load duration; racking load; roofs; sheathing; strength tests; tensile load; transverse load; walls


Related Resources:
  • This link has not been checked.ASTM
    "provides a global forum for the development and publication of voluntary consensus standards for materials, products, systems, and services"

This publication in whole or part might be found online. Check the sources on the related article below. Or use search engines on the web.

Related Concepts


Author Information and Other Publications Notes
ASTM
  1. ASTM C991-03 Standard Specification for Flexible Glass Fiber Insulation for Metal Buildings
  2. C1046-95, Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components
  3. C1060-90(1997)e1 Standard Practice for Thermographic Inspection of Insulation Installations in Envelope Cavities of Frame Buildings
  4. C1134-90(2001) Standard Test Method for Water Retention of Rigid Thermal Insulations Following Partial Immersion
  5. C1155-95, Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data
  6. C1193-00 Standard Guide for Use of Joint Sealants
  7. C1199-00 standard test method for measuring the steady-state thermal transmittance of fenestration systems using hot box methods
  8. C1363-97 standard test method for the thermal performance of building assemblies by means of a hot box apparatus
  9. C1498-01 standard test method for hygroscopic sorption isotherms of building materials
  10. C168-01 Standard Terminology Relating to Thermal Insulating Materials
  11. C177-85 Standard test method for steady-state heat flux measurements and thermal transmission properties by means of the guarded-hot-plate apparatus
  12. C209-98 standard test methods for cellulosic fiber insulating board
  13. C236-89, Standard test method for steady-state thermal performance of building assemblies by means of a guarded hot box
  14. C518-91, Standard test method for steady-state heat flux measurements and thermal transmission properties by means of the heat flow meter apparatus
  15. C755-85 Standard practice for selection of vapor retarders for thermal insulation
  16. C976-90(1996)e1 standard test method for thermal performance of building assemblies by means of a calibrated hot box
  17. D1413-76 Standard method of testing wood preservatives by laboratory soil block culture
  18. D3273-00 Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber
  19. D3274-95 Standard Test Method for Evaluating Degree of Surface Disfigurement of Paint Films by Microbial (Fungal or Algal) Growth or Soil and Dirt Accumulation
  20. D3679-02 Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Siding
  21. D4442-92(1997)e1 standard test methods for direct moisture content measurement of wood and wood-base materials
  22. D4444-92e1 standard test methods for use and calibration of hand-held moisture meters
  23. D4933-99 Standard guide for moisture conditioning of wood and wood-base materials
  24. D6329-98 standard guide for developing methodology for evaluating the ability of indoor materials to support microbial growth using static environmental chambers
  25. E1105-00 Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform or Cyclic Static Air Pressure Difference
  26. E1186-98 Standard practices for air leakage site detection in building envelopes and air retarder systems
  27. E1258-88 Standard Test Method for Airflow Calibration of Fan Pressurization Devices
  28. E1424-91, Standard test method for determining the rate of air leakage through exterior windows, curtain walls, and doors under specified pressure and temperature differences across the specimen
  29. E1503-06 Standard Test Method for Conducting Outdoor Sound Measurements Using a Digital Statistical Sound Analysis System
  30. E1557-02 standard classification for building elements and related sitework-UNIFORMAT II
  31. E1646-95 Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference
  32. E1677-95(2000) standard specification for an air retarder (AR) material or system for low-rise framed building walls
  33. E1700-95(1999), standard classification for serviceability of an office facility for structure and building envelope
  34. E1825-96 Standard Guide for Evaluation of Exterior Building Wall Materials, Products, and Systems
  35. E1825-96, standard guide for evaluation of exterior building wall materials, products, and systems
  36. E1827-96 Standard Test Methods for Determining Airtightness of Buildings Using an Orifice Blower Door
  37. E1827-96(2002) Standard Test Methods for Determining Airtightness of Buildings Using an Orifice Blower Door
  38. E2099-00 standard practice for the specification and evaluation of pre-construction laboratory mockups of exterior wall systems
  39. E2099-00, standard practice for the specification and evaluation of pre-construction laboratory mockups of exterior wall systems
  40. E2128-01a Standard Guide for Evaluating Water Leakage of Building Walls
  41. E241-04 Standard Guide for Limiting Water-Induced Damage to Buildings
  42. E283-04, standard test method for rate of air leakage through exterior windows, curtain walls and doors
  43. E29-04 standard practice for using significant digits in test data to determine conformance with specifications
  44. E330-02 standard test method for structural performance of exterior windows, curtain walls, and doors by uniform static air pressure difference
  45. E331-00 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference
  46. E331-00, Standard test method for water penetration of exterior windows, curtain walls, and doors by uniform static air pressure difference
  47. E547-00: water penetration of exterior windows, curtain walls, and doors by cyclic static air pressure differential
  48. E631-93a(1998)e1 Standard Terminology of Building Constructions
  49. E632-82(1996) standard practice for developing accelerated tests to aid prediction of the service life of building components and materials
  50. E74-04 standard practice of calibration of force-measuring instruments for verifying the force indication of testing machines
  51. E741-00 Standard Test Method for Determining Air Change in a Single Zone by Means of a Tracer Gas Dilution
  52. E773-01, Standard test method for accelerated weathering of sealed insulating glass units
  53. E779-03, ASTM Method for Determining Air Leakage Rates by Fan Pressurization Test
  54. E779-99 Standard test method for determining air leakage rate by fan pressurization
  55. E783-02 standard test method for field measurement of air leakage through installed exterior windows and doors
  56. E917-99 standard practice for measuring life-cycle costs of buildings and building systems
  57. E964-93(1998)e1 Standard Practice for Measuring Benefit-to-Cost and Savings-to-Investment Ratios for Buildings and Building Systems
  58. E96-93 Standard test methods for water-vapor transmission of materials
  59. F1249-90(1995) Standard Test Method for Water Vapor Transmission Rate Through Plastic Film and Sheeting Using a Modulated Infrared Sensor
  60. F372-99 Standard Test Method for Water Vapor Transmission Rate of Flexible Barrier Materials Using an Infrared Detection Technique
  61. G84-89(1999)e1 standard practice for measurement of time-of-wetness on surfaces exposed to wetting conditions as in atmospheric corrosion testing
  62. Heat transmission measurements in thermal insulations
  63. Performance of exterior envelopes of whole buildings VIII: integration of building envelopes
  64. Standard guide for statistical evaluation of indoor air quality models. ASTM D 5157-97  



CRDBER, at CBS, BCEE, ENCS, Concordia,