Conceptual Reference Database for Building Envelope Research Prev
Next

Estimation of risk of high moisture conditions in an external wall

Harderup, E.
1997
Duribility of Building Materials and Components 7, vol 1, pp. 161-169
vapour diffusion, pelting rain, moisture transfer, occurrence of hight moisture conditions


Harderup, E., (1997), "Estimation of risk of high moisture conditions in an external wall", Duribility of Building Materials and Components 7, vol 1, pp. 161-169.
Abstract:

The paper shows results from two moisture loads in a Moisture Design. The primary results concern calculations of moisture transfer of vapour diffusion, in combination with or without pelting rain, for three different locations in Sweden. The construction is an appratment wall with south and north facings. Hourly values of the бн.


Related Resources:


Related Concepts


Author Information and Other Publications Notes
Harderup, E.
Lund University, Moisture Design of Building,
  1. Moisture conditions at the outer surface of constructions with negligible heat and moisture capacity
  2. Moisture conditions in a north-facing wall with cellulos loose-fill insulation: construction with and without a vapor retarder and air leakage
  3. Moisture control in buildings - how can varying outdoor climate be allowed for?  



CRDBER, at CBS, BCEE, ENCS, Concordia,