Conceptual Reference Database for Building Envelope Research Prev
Next

A systematic method for hygrothermal analysis of building constructions using computer models

Geving, S.
1997
Proceedings of Building Simulation '97, Volume 2: 355-361


Geving, S., (1997), "A systematic method for hygrothermal analysis of building constructions using computer models", Proceedings of Building Simulation '97, Volume 2: 355-361.
Abstract:
Knowledge of the expected long-termperformance of building envelopes subjected to simultaneous heat and moisture transport is critical during the design state. The last few years a number of the practical hygrothermal simulation models have been developed that can be used to analyse the combined heat and moisture behaviour of building constructions. Howerver, hygrothermal analysis using computer tools is not a straightforward task. In this paper is presented a general systematic method for hygrothermal analysis of buidling constructions by the use of simulation models The mehtod is applied on a design case of a wood frame wall, evaluating the risk for mould growth within the construction.

Other refs:

Geving, Stig; Karagiozis, Achilles; Salonvaara, Mikael, Measurements and two-dimensional computer simulations of the hygrothermal performance of a wood frame wall. Journal of thermal insulation and building envelopes. Technomic Publ. 20, 301-319 1997

Moiture design load: Geving, S. 2000. Hygrothermal analysis of building structures using computer models. Journal of Thermal Envelope & Building Science 23(3): 224-243.


Related Resources:

This publication in whole or part might be found online. Check the sources on the related article below. Or use search engines on the web.

Related Concepts


Author Information and Other Publications Notes
Geving, S.
Stig Geving Department of Building and Construction Engineering The Norwegian University of Science and Technology (NTNU) Alfred Getz v 3, N-7034 Trondheim, Norway
  1. Hygrothermal analysis of building structures using computer models
  2. Measurements and two-dimensional computer simulations of the hygrothermal performance of a wood frame wall
  3. The drying potential and risk for mold growth in compact wood frame roofs with built-in moisture  