Conceptual Reference Database for Building Envelope Research Prev
Next

Proposed method for calculating water penetration test parameters of wall assemblies as applied to Istanbul, Turkey

Sahal, N. and Lacasse, M. A.
2008
Building and Environment, 43(7): 1250-1260


Sahal, N. and Lacasse, M. A., (2008), "Proposed method for calculating water penetration test parameters of wall assemblies as applied to Istanbul, Turkey", Building and Environment, 43(7): 1250-1260.
Abstract:
Water penetration of a building envelope assembly is typically assessed on the basis of the degree of watertightness (i.e. lack of water ingress) of the components of the assembly when subjected to simulated driving rain conditions. Test standards provide the magnitude and extent of these test conditions as suggested by the test parameters, i.e. the water spray rates and pressure differences and the dwell time over which these are to be applied. Such conditions would presume to simulate driving rain and wind conditions of locations spread over a broad geographical area. For example, the water spray rate suggested for use in watertightness performance tests in EN 12155-Curtain walling-watertightness-laboratory test under static pressure-is considered appropriate for simulating driving rain and wind conditions for locations across Europe. However, test parameters should be based on the expected driving rain intensities and wind pressures that are likely to occur for a specific climate and a given return period. It might also be based on the building type (e.g. high or low-rise building), or even on the location on the building fa?ade. Hence, a method is required for calculating water penetration test parameters for specific buildings located in a specific climate. The purpose of this paper is to propose a method for calculating water penetration test parameters. A survey of existing methods is first provided that focuses on the quantification of driving rain on buildings and thereafter, calculation of water penetration test parameters. The merits and drawbacks of these methods are then discussed. Based on this review, a method for calculating test parameters is proposed and is applied to developing water penetration test parameters for Istanbul, Turkey. A comparison of test parameters calculated from the proposed method with those given in existing Turkish standards TS EN 12155-Curtain walling-watertightness-laboratory test under static pressure¡ªand TS ENV 13050¡ªCurtain walling-watertightness-laboratory test under dynamic condition of air pressure and water spray¡ªrelated to Istanbul, indicated that the water spray rate given in the TS standards is higher than spray rates calculated from the proposed method for return periods of 5, 10 and 30 years.

Keywords: Driving rain; Building envelope; Test parameters; Watertightness; Water penetration; Water leakage

This link has not been checked.Online source


This publication in whole or part might be found online. Check the sources on the related article below. Or use search engines on the web.

Related Concepts


Author Information and Other Publications Notes
Sahal, N.
     
Lacasse, M. A.
Institute for Research in Construction, National Research Council, Ottawa,
  1. A discrete stochastic model for performance prediction of roofing systems
  2. A methodology to develop moisture management strategies for wood-frame walls in North America: application to stucco-clad walls
  3. An approach to validating computational models for hygrothermal analysis - full scale experiments
  4. Benchmarking of the advanced hygrothermal model hygIRC with mid scale experiments
  5. Defining climate regions as a basis for specifying requirements for precipitation protection for walls
  6. Durability of Building Materials and Components 8
  7. Executive Summary of Research Contributions Related to Moisture Management of Exterior Wall Systems (MEWS) - Modeling, Experiments, and Benchmarking
  8. Final Report from Task 8 of MEWS Project (T8-03) - Hygrothermal Response of Exterior Wall Systems to Climate Loading: Methodology and Interpretation of Results for Stucco, EIFS, Masonry and Siding Clad Wood-Frame Walls
  9. MEWS methodology for developing moisture management strategies: application to stucco-clad wood-frame walls in North America
  10. Report from Task 2 of MEWS Project - Description of 17 Large Sale Wall Specimens Built for Water Entry Investigation in IRC Dynamic Wall Testing Facility
  11. Report from task 6 of MEWS project -- experimental assessment of water penetration and entry into wood-frame wall specimens, - final report
  12. Report from Task 8 of MEWS Project - MEWS Methodology for Developing Moisture Management Strategies - Application to Stucco Clad Wood-Frame Walls in North America  



CRDBER, at CBS, BCEE, ENCS, Concordia,