Conceptual Reference Database for Building Envelope Research Prev
Next

A prototype photovoltaic/thermal system integrated with transpired collector

Athienitis, A. K., Bambara, J., O'neill, B. and Faille, J.
2011
Solar Energy, 85(1): 139-153
Keywords: Building-integrated photovoltaic/thermal system; Unglazed transpired collector; Air preheating; Equivalent efficiency


Athienitis, A. K., Bambara, J., O'neill, B. and Faille, J., (2011), "A prototype photovoltaic/thermal system integrated with transpired collector", Solar Energy, 85(1): 139-153.
Abstract:
Building-integrated photovoltaic/thermal (BIPV/T) systems may be utilized to produce useful heat while simultaneously generating electricity from the same building envelope surface. A well known highly efficient collector is the open-loop unglazed transpired collector (UTC) which consists of dark porous cladding through which outdoor air is drawn and heated by absorbed solar radiation. Commercially available photovoltaic systems typically produce electricity with efficiencies up to about 18%. Thus, it is beneficial to obtain much of the normally wasted heat from the systems, possibly by combining UTC with photovoltaics. Combination of BIPV/T and UTC systems for building facades is considered in this paper ¨C specifically, the design of a prototype fa??ade-integrated photovoltaic/thermal system with transpired collector (BIPV/T). A full scale prototype is constructed with 70% of UTC area covered with PV modules specially designed to enhance heat recovery and compared to a UTC of the same area under outdoor sunny conditions with low wind. The orientation of the corrugations in the UTC is horizontal and the black-framed modules are attached so as to facilitate flow into the UTC plenum. While the overall combined thermal efficiency of the UTC is higher than that of the BIPV/T system, the value of the generated energy ¨C assuming that electricity is at least four times more valuable than heat ¨C is between 7% and 17% higher. Also, the electricity is always useful while the heat is usually utilized only in the heating season. The BIPV/T concept is applied to a full scale office building demonstration project in Montreal, Canada. The ratio of photovoltaic area coverage of the UTC may be selected based on the fresh air heating needs of the building, the value of the electricity generated and the available building surfaces.

Related Resources:

This publication in whole or part may be found online at: This link has not been checked.here.

Related Concepts


Author Information and Other Publications Notes
Athienitis, A. K.
Department of Building, Civil, and Environmental Engineering, Concordia University, Montreal
  1. A methodology for simulation of daylight room illuminance distribution and light dimming for a room with a controlled shading device
  2. A review of research activities in energy efficiency in buildings in Canada
  3. A study of design options for a building integrated photovoltaic/thermal (BIPV/T) system with glazed air collector and multiple inlets
  4. Building simulation in a mathematical programming environment
  5. Comparaison de m¨¦thodes de mesure de flux de chaleur pour sp¨¦cimens de grandes et moyennes dimensions
  6. Daylighting performance evaluation of a bottom-up motorized roller shade
  7. Design and construction of an environmental chamber facility
  8. design and thermal performance of a BIPV/T system thermally coupled with a ventilated concrete slab in a low energy solar house: Part 2, ventilated concrete slab
  9. Design Methodology of Solar Neighborhoods
  10. Environmental chamber for investigation of building envelope performance
  11. Essai sur les toits plats isol¨¦s ¨¤ la fibre de cellulose
  12. Experimental study of the thermal performance of a large institutional building with mixed-mode cooling and hybrid ventilation
  13. Impact of air leakage pattern on reinsulated walls
  14. Indoor thermal environmental conditions near glazed facades with shading devices ?Part I: Experiments and building thermal model
  15. Investigation of the thermal performance of a passive solar test-room with wall latent heat storage
  16. Modeling of energy performance of a house with three configurations of building-integrated photovoltaic/thermal systems
  17. Modeling, design and thermal performance of a BIPV/T system thermally coupled with a ventilated concrete slab in a low energy solar house: Part 1, BIPV/T system and house energy concept
  18. Numerical model of a building with transparent insulation
  19. Simulation of fa?ade and envelope design options for a new institutional building
  20. Study of the reduced impact of thermal bridges in two sprayed-applied polyurethane wall assemblies
  21. Testing of flat roofs insulated with cellulose fiber
  22. Use of an environmental chamber to investigate large-scale envelope specimen hygrothermal performance  
Bambara, J.
     
O'neill, B.
     
Faille, J.
     



CRDBER, at CBS, BCEE, ENCS, Concordia,