Conceptual Reference Database for Building Envelope Research Prev
Next

Numerical model of a building with transparent insulation

Athienitis, A. K. and Ramadan, H.
1999
Solar Energy, 67(1?): 101-109


Athienitis, A. K. and Ramadan, H., (1999), "Numerical model of a building with transparent insulation", Solar Energy, 67(1?): 101-109.
Abstract:
An explicit finite difference simulation model is developed to study the thermal performance of an outdoor test-room with one transparently insulated (TI) wall. The thermal behavior of the room is examined under different control strategies for the shading device and for air flow through the TI wall to the room. Simulation results indicate significant energy savings with practically no auxiliary heating required on cold sunny days in Montreal. However, appropriate control strategies are required to prevent overheating of the room and discomfort. Air flow through the TI wall and then into the room succeeds in lowering its room surface temperature to less than 31°C and reducing to zero the auxiliary heating required on any clear day. Blind control is based on several criteria, including outside temperature, room-facing surface temperature of TI wall (not to exceed 29°C) and room air temperature not to exceed a certain maximum.

This publication in whole or part may be found online at: This link has not been checked.here.
Author Information and Other Publications Notes
Athienitis, A. K.
Department of Building, Civil, and Environmental Engineering, Concordia University, Montreal
  1. A methodology for simulation of daylight room illuminance distribution and light dimming for a room with a controlled shading device
  2. A prototype photovoltaic/thermal system integrated with transpired collector
  3. A review of research activities in energy efficiency in buildings in Canada
  4. A study of design options for a building integrated photovoltaic/thermal (BIPV/T) system with glazed air collector and multiple inlets
  5. Building simulation in a mathematical programming environment
  6. Comparaison de m¨¦thodes de mesure de flux de chaleur pour sp¨¦cimens de grandes et moyennes dimensions
  7. Daylighting performance evaluation of a bottom-up motorized roller shade
  8. Design and construction of an environmental chamber facility
  9. design and thermal performance of a BIPV/T system thermally coupled with a ventilated concrete slab in a low energy solar house: Part 2, ventilated concrete slab
  10. Design Methodology of Solar Neighborhoods
  11. Environmental chamber for investigation of building envelope performance
  12. Essai sur les toits plats isol¨¦s ¨¤ la fibre de cellulose
  13. Experimental study of the thermal performance of a large institutional building with mixed-mode cooling and hybrid ventilation
  14. Impact of air leakage pattern on reinsulated walls
  15. Indoor thermal environmental conditions near glazed facades with shading devices ?Part I: Experiments and building thermal model
  16. Investigation of the thermal performance of a passive solar test-room with wall latent heat storage
  17. Modeling of energy performance of a house with three configurations of building-integrated photovoltaic/thermal systems
  18. Modeling, design and thermal performance of a BIPV/T system thermally coupled with a ventilated concrete slab in a low energy solar house: Part 1, BIPV/T system and house energy concept
  19. Simulation of fa?ade and envelope design options for a new institutional building
  20. Study of the reduced impact of thermal bridges in two sprayed-applied polyurethane wall assemblies
  21. Testing of flat roofs insulated with cellulose fiber
  22. Use of an environmental chamber to investigate large-scale envelope specimen hygrothermal performance  
Ramadan, H.
     



CRDBER, at CBS, BCEE, ENCS, Concordia,