Monitoring of the building envelope of a heritage house: a case study

Sa?d, M. N. A., W. C. Brown, C. J. Shirtliffe and A. H. P. Maurenbrecher
1999
Energy and Buildings, 30(3): 211-219
Thermal; Moisture; Building envelope; Monitoring; Heritage house; Masonry


Sa?d, M. N. A., W. C. Brown, C. J. Shirtliffe and A. H. P. Maurenbrecher, (1999), "Monitoring of the building envelope of a heritage house: a case study", Energy and Buildings, 30(3): 211-219.
Abstract:
The paper describes the long-term monitoring of the hygrothermal performance of the building envelope of a heritage house located in Ottawa. The house, once the residence of two of Canada's Prime Ministers, now serves as a museum. To preserve the historical artifacts within the building, the specified temperature and relative humidity (RH) for the indoor air are 21ˇăC and 35% to 50%, respectively. As the house must also be preserved, there was concern about the effect of the high indoor RH (moisture) on the durability of the building structure. The main objective of the monitoring was to assess the effect of the conditioned air on the building envelope. Selected wall sections and a window were continuously monitored from March 1995 to August 1996. The monitoring included indoor and outdoor conditions and the attic environment. Temperature, RH, surface wetting-drying cycles (from precipitation or condensation), and air-pressure differential were monitored. This paper describes the monitoring approach and results. The results indicated that the brick walls are unlikely to experience internal condensation problems as long as they are subjected to a negative air pressure difference. However, because the building is quite leaky, the negative pressure introduced too much cold dry air from the exterior. It caused localized cold spots with condensation and ice formation on interior of walls and ceiling. Negative air pressure differences are not a solution unless the leakage paths are reduced.

Related Resources:

This publication in whole or part might be found online. Check the sources on the related article below. Or use search engines on the web.

Related Concepts


Author Information and Other Publications Notes
Sa?d, M. N. A.
Institute for Research in Construction, National Research Council Canada, Division of Building Research, Ottawa, Canada K1A 0R6
  1. Long-Term field monitoring of an EIFS clad wall  
Brown, W. C.
     
Shirtliffe, C. J.
  1. Monitoring the hygrothermal performance of a masonry wall with and without thermal insulation  
Maurenbrecher, A. H. P.
Institute for Research in Construction, National Research Council Canada, Division of Building Research, Ottawa, Canada K1A 0R6
  1. Monitoring the hygrothermal performance of a masonry wall with and without thermal insulation
  2. Review of factors affecting the durability of repointing mortars for older masonry  



CRDBER, at CBS, BCEE, ENCS, Concordia,