Conceptual Reference Database for Building Envelope Research Prev
Next
Related Concept
  • experiments and testing



  • Related Articles
  • Building Engineering Group (BEG)
  • Morrison Hershfield - Building Engineering & Management
  • What Causes Wind? And How is Wind Measured?

  • Concept:

    experiment: field testing and monitoring programs

    Waterloo

    VTT

    NET Natural Exposure Test Facility at WMEL http://www.energy.wsu.edu/projects/building/moisture.cfm
    Related References
    --------
    A "follow-up" study of moisture conditions and performance of moisture sensors in flat roofs provided with exterior insulation in the late seventies, by Christensen, G. and Bunch-nielsen, T., 2002
    --------
    A field study of indoor moisture problems and damage in new northwest homes, by Tsongas, G., 1992
    --------
    A field study of the moisture performance of roofs of occupied newly constructed timber framed houses, by Cunningham, M.J., M.R. Bassett, D. McQuade, and M. Beckett, 1994
    investigations of damaged houses
    A qualitative model for moisture balance in painted vertical wood paneling, by Hjort, S. G., 1998
    --------
    Air sampling results in relation to extent of fungal colonization of building materials in some water-damaged buildings, by Miller, J.D., Haisley, P.D. and Reinhardt, J.H, 2000
    --------
    Airtightness testing of two- and three-unit buildings with a single fan, by Depani, S. and Fazio, P., 2005
    --------
    Building envelope design, Part 2: estimating field performance of thermal insulation, by Bomberg, M. T. and Kumaran, M. K., 1993
    --------
    Building envelope performance monitoring, by Hubbs, B., Eng., P. and Hircock, M., 0
    --------
    Field experience with moisture management -- putting principles into practice, by Brown W. , Chouinard K. , Lawton M. , Patenaude A. , Vlooswyk J., 2003
    --------
    Field measurement of uncontrolled airflow and depressurization in restaurants, by Cummings, J. B., Fairey, P. W., Withers, C. R. J., Mckendry, B. B. and Moyer, N. A., 1996
    --------
    Field observations and laboratory tests of water migration in walls with shiplap hardboard siding, by Tsongas, G. A., Govan, D. P. and J. A. McGillis, 1998
    --------
    Guidelines for on-site measurement of moisture in wood building materials, by Forintek Canada Corporation, 2001
    --------
    Heat and moisture response of vented and compact cathedral ceilings: a test house evaluation, by Hens, H. and Janssens, A., 1999
    --------
    High accuracy heat flow calculation - a method to calculate the heat flow for an arbitrary wall with constant material properties in a natural climate, by Anderlind, G., 1997
    --------
    In-Situ performance evaluation of exterior insulation basement systems (EIBS) - spray polyurethane foam: summary report, by Swinton, M. C., Bomberg, M. T., Kumaran, M. K., Maref, W., Normandin, N. and Marchand, R. G., 2000
    --------
    Long-Term field monitoring of an EIFS clad wall, by Sa?d, M. N. A., Brown, W. C. and Walker, I. S., 1997
    --------
    Measurement of heat and mass transfer between the lower and upper floors of a house, by Riffat, S. B., 1989
    --------
    Methodology and design of field experiments for monitoring the hygrothermal performance of wood frame enclosures , by Straube, J., Onysko, D. and Schumacher, C., 2002
    exterior wall
    Moisture conditions of outdoor air ventilated crawl spaces in apartment buildings in a cold climate, by Kurnitski, J. and Matilainen, M., 2000
    test house
    Moisture in combined concrete timber-frame walls without vapour barrier, by Stang, B. D., Nicolajsen, A. and Hansen, M. H., 2002
    --------
    Moisture transport and convection in building envelopes - ventilation in light weight outer walls, by Gudum, C., 2003
    --------
    Monitoring of the building envelope of a heritage house: a case study, by Sa?d, M. N. A., W. C. Brown, C. J. Shirtliffe and A. H. P. Maurenbrecher, 1999
    --------
    Monitoring the hygrothermal performance of a masonry wall with and without thermal insulation, by Maurenbrecher, A. H. P., Rousseau, M. Z., Said, M. N. and Shirtliffe, C. J., 1998
    experimental house
    On controlling indoor thermal and moisture content for an occupied building, by Lu, X. S. and Viljanen, M., 2000
    --------
    On the influence of cavity ventilation on moisture content in timber frame walls, by Hansen, M. H., Nicolajsen, A. and Stang, B. D., 2002
    sampling airborne fungi: culture and microscopic examination
    Prevalence of culturable airborne fungi in 100 U.S. office buildings in the building assessment survey and evaluation (BASE) study, by Macher, J.M., F. C. Tsai, L.E. Burton, K.Liu, and J. M. Waldman, 2001
    --------
    Simulation support for performance assessment of building components, by Strachan, P. A., 2008
    --------
    Water intrusion evaluation for caulkless siding, window, and door systems-laboratory testing results, by NAHB Research Center, Inc., 2002
    --------
    Wireless sensor networks as part of a web-based building environmental monitoring system, by Jang, W., Healy, W. M. and Skibniewski, M. J., 2008




    CRDBER, at CBS, BCEE, ENCS, Concordia,