- lab measurement, drying rate, low-slope
- A capacitance probe for measurement of moisture content in open pore thermal insulations, by Motakef, S., and L.R. Glicksman, 1989
- wighing system for specimen (8'by8')
- A precision weighing system for helping assess the hygrotherma response of full-scale wall assemblies, by Maref, W.M. Lacasse, M.A. and Krouglicof, N., 2001
- --------
- An experimental device for the measurement of hygroscopic inertia influence on RH variation, by Ramos, N. M. M. and De_Freitas, V. P., 2009
- fire retarder added to smart vapor barrier
- Application of a new type of air and vapor retarder in a self-drying sloped roof with a cathedral ceiling, by Hens, H. and Janssens, A., 1998
- use experimental data to validate models
- Applied moisture engineering, by Karagiozis, A. N., 1998
- ASTM hot box
- C1363-97 standard test method for the thermal performance of building assemblies by means of a hot box apparatus, by ASTM, 1997
- condensation in highly insulated wood frame walls
- Condensation potential in high thermal performance walls -- cold winter climate, by Sherwood, G. E., 1983
- environmental chamber facility, envelope
- Design and construction of an environmental chamber facility, by Fazio, P., Athienitis, A. K., Marsh, C. and Rao, J., 1994
- --------
- Environmental chamber for investigation of building envelope performance, by Fazio, P., Athienitis, A., Marsh, C. and Rao, J., 1997
- --------
- Estimating values for the moisture source load and buffering capacities from indoor climate measurements, by Schijndel, A. W. M. v., 2008
- environmental chamber
- Experimental setup for the study of air leakage patterns, by Desmarais, G., Derome, D., Fazio, P., 1998
- --------
- Final Report from Task 8 of MEWS Project (T8-03) - Hygrothermal Response of Exterior Wall Systems to Climate Loading: Methodology and Interpretation of Results for Stucco, EIFS, Masonry and Siding Clad Wood-Frame Walls, by Beaulieu, P., Bomberg, M., Cornick, S., Dalgliesh, A., Desmarais, G., Djebbar, R., Kumaran, K., Lacasse, M., Lackey, J. Maref, W., et al., 2002
- --------
- Full-scale testing of indoor humidity and moisture buffering in building materials, by Mitamura, T., C. Rode and J. Schultz, 2001
- air leakage patterns in walls
- Impact of air leakage pattern on reinsulated walls, by Desmarais, G., Derome, D., Athienitis, A. K. and Fazio, P., 1998
- lab measurement, drying rate, low-slope
- Laboratory measurements of the drying rates of low-slope roofing systems, by Desjarlais, A.O., D.M. Kyle, P.W. Childs, and J.E. Christian, 1994
- ECF testing on flat roof
- Large scale testing of two flat roof assemblies insulated with cellulose, by Derome, D. and Fazio, P., 1998
- at Environmental Chamber
- Measuring air leakage of full-scale curtain wall sections using a non-rigid air-chamber method, by Fazio, P., H. Ge, and J. Rao, 2001
- --------
- MEWS methodology for developing moisture management strategies: application to stucco-clad wood-frame walls in North America, by Beaulieu, P.; Cornick, S.M.; Dalgliesh, W.A.; Djebbar, R.; Kumaran, M.K.; Lacasse, M.A.; et al., 2001
- flat roof
- Rapport Final Projet Site Internet - L'enveloppe du batiment et l'efficacit¨¦ ¨¦nerg¨¦tique, by Derome, D. and Fazio, P., 1998
- --------
- Review and framework for large-scale laboratory studies on wetting and drying of building envelopes, by Fazio, P., Derome, D. and Rao, J., 2001
- microcalorimetry to measure mold growth
- Studies of the degratation of building materials by isothermal microcalorimetry, by Wadso, L., 1996
- --------
- System for testing the hygrothermal performance of multi-layered building envelopes , by Pavl¨ªk, Z., Pavli¨ªk, J., Jirickov¨¢, M. and Cerny, R., 2002
- experimental climate chamber controls the water vapour flux
- The role of absorbent materials in moderating changes of relative humidity, by Padfield, T., 1998
|