Measuring air leakage characteristics with flexible double air chambers
Fazio, P., Rao, J., and Ge, H.
2002 Journal of Architectural Engineering, 8(3), 89-95
Fazio, P., Rao, J., and Ge, H., (2002), "Measuring air leakage characteristics with flexible double air chambers", Journal of Architectural Engineering, 8(3), 89-95.
Abstract: |
The fan pressurization method for measuring air leakage through the building envelope relies on the assumption that the extraneous air leakage (EAL) through paths other than those through the specimen being tested is negligible. When EAL does exist, the calibration procedure by ASTM Standard E-283 is used to measure EAL values by covering the specimen or guarded chambers are used to equalize the pressure differences across these unintended paths. A new testing method, the flexible double-chamber method, is presented in this paper for large specimens where the above two approaches are difficult to implement and where flexible chambers are more easily applied. The experimental procedure and data processing routine are presented for the case of a full-size metal curtain wall specimen. The EAL is estimated by regression analysis in data processing. Inference analysis, multivariate error analysis, and the Mo nte Carlo simulation tech nique are also presented to examine the estimation errors.
.
See also: Fazio et al., 2001, Measuring air leakage of full-scale curtain wall sections using a non-rigid air-chamber method |
|
|
This publication in whole or part might be found online. Check the sources on the related article below. Or use search engines on the web.
|
Related Concepts
|
Related Resources:
|