Methods for the assessment of moisture content of envelope assemblies
Derome, D., Teasdale-St-Hilaire, A. and Fazio, P.
2001 Proceedings for Performance of Exterior Envelopes of Whole Buildings VIII: Integration of Building Envelopes, December 2-7, Clearwater Beach, Florida
Derome, D., Teasdale-St-Hilaire, A. and Fazio, P., (2001), "Methods for the assessment of moisture content of envelope assemblies", Proceedings for Performance of Exterior Envelopes of Whole Buildings VIII: Integration of Building Envelopes, December 2-7, Clearwater Beach, Florida.
Abstract: |
Buildings VIII/Wall Performance¡ªPractices 1
ABSTRACT
Unlike heat transfer, the rate of transfer of moisture cannot be measured directly. Most methods are intrusive. Different materials react differently in the presence of moisture and the sustained presence of moisture can degrade the materials¡ªa process that may affect the measurements. However, many studies focus on the impact of moisture within building envelope assemblies brought in either by diffusion, air leakage, capillarity, or water ingress. In an effort to contribute to the development of more standard procedures to measure moisture for experimental applications, this paper presents a review of the various methods available to monitor the presence of moisture in envelope materials. These include gravimetry, electrical resistance techniques, dielectric techniques, neutron thermalization methods, thermal conductivity methods, ultrasonic methods, spectroscopic analysis, and thermal imaging. The advantages and disadvantages of each method are discussed, as well as a framework for the selection of the instruments and methods with respect to the testing protocol. |
|
|
|
Related Concepts
|