Abstract:
A protocol to evaluate the overall performance of the building envelope is not yet available in North America. Consequently neither the manufacturer nor the client can be sure of the performance of the unit over time. In the Canadian climate, the performance of wood-frame building envelopes is directly affected by moisture management, as well as by the quality of design, construction workmanship, and maintenance. Trapped moisture reduces the thermal performance of the envelope and can lead to mould growth that deteriorates building materials and contaminates the indoor-air. The means to evaluate the impact of these factors on the overall performance of the envelope are limited. The computer models that exist are still, for the most part, reserved for researchers or have not been validated to a sufficient comfort level for the designer. Large scale testing that would provide realistic results have been limited due to the lack of facilities and the lack of evaluation procedures.

This link was checked on Dec. 2006Full paper (Concordia User only)


This publication in whole or part might be found online. Check the sources on the related article below. Or use search engines on the web.

Related Concepts


Author Information and Other Publications Notes
Horvat, M.
  1. IFC-based framework for evaluating total performance of building envelopes
  2. Protocol and assessment tool for performance evaluation of light-frame building envelopes used in residential buildings  
Fazio, P.
Paul Fazio, Professor of Building, Civil & Environmental Engineering, Concordia University, Montreal
  1. A limit state design (LSD) approach for comparing relative drying performance of wood-frame envelope systems with full-scale lab, A roadmap towards intelligent net zero- and positive-energy buildings,
  2. A new test method to determine the relative drying capacity of building envelope panels of various configurations
  3. A new testing method to evaluate the relative drying performance of different building envelope systems using water trays
  4. A quantitative study for the measurement of driving rain exposure in the Montr¨¦al region
  5. A review of research activities in energy efficiency in buildings in Canada
  6. Airtightness testing and air flow modeling of two and three-unit multifamily buildings
  7. Airtightness testing of two- and three-unit buildings with a single fan
  8. Approach for the simulation of wetting due to rain infiltration for building envelope testing
  9. Approach for urban driving rain index by using climatological data recorded at suburban meteorological station
  10. Behavior of wall assemblies with different wood sheathings wetted by simulated rain penetration
  11. Building Physics: 3rd International Conference in Building Physics
  12. Building pressurisation can affect possibility of mould growth
  13. Cavity pressure in rain screen walls
  14. Comparaison de m¨¦thodes de mesure de flux de chaleur pour sp¨¦cimens de grandes et moyennes dimensions
  15. Continuous folded plate structures under uniform load
  16. Creative case adaptation for building engineering design
  17. Design and construction of an environmental chamber facility
  18. Design Methodology of Solar Neighborhoods
  19. Development of experimental procedure to evaluate potential movement of mold spores from wall cavity to indoor environment
  20. Development of HAM tool for building envelope analysis
  21. Effect of capillarity on rainwater penetration in the building envelope
  22. Environmental chamber for investigation of building envelope performance
  23. Essai sur les toits plats isol¨¦s ¨¤ la fibre de cellulose
  24. Evaluation of radiance's genBSDF capability to assess solar bidirectional properties of complex fenestration systems
  25. Experimental evaluation of potential transport of mold spores from moldy studs in full-size wall assemblies
  26. Experimental setup for the study of air leakage patterns
  27. Experimental study of temperature distributions across two curtain wall systems
  28. Folded sandwich plate structures
  29. Identification and transport investigation of microbial volatile organic compounds in full-scale stud cavities
  30. IFC-based framework for evaluating total performance of building envelopes
  31. Impact of added insulation on air leakage patterns
  32. Impact of air leakage pattern on reinsulated walls
  33. In-cavity evaporation allowance--A drying capacity indicator for wood-frame wall system
  34. Influence of air space on multi-layered material water vapor permeability measurement
  35. Influence of facade geometry on weathering
  36. Integrated analysis of whole building heat, air and moisture transfer
  37. Interzonal air and moisture transport through large horizontal openings in a full-scale two-story test hut: Part 1 - Experimental study
  38. Interzonal air and moisture transport through large horizontal openings in a full-scale two-story test-hut: Part 2- CFD study
  39. Large scale testing of two flat roof assemblies insulated with cellulose
  40. Mapping of air leakage in exterior wall assemblies
  41. Measuring air leakage characteristics with flexible double air chambers
  42. Measuring air leakage of full-scale curtain wall sections using a non-rigid air-chamber method
  43. Methods for the assessment of moisture content of envelope assemblies
  44. Modeling of moisture behavior of wood planks in nonvented flat roofs
  45. Modelling of indoor air humidity: the dynamic behaviour within an enclosure
  46. Moisture buffering capacities of five North American building materials
  47. Moisture performance of leaky exterior walls with added insulation
  48. Nonlinear elastic analysis of panelized shear sandwich walls
  49. Numerical investigation of the influence of room factors on HAM transport in a full-scale experimental room
  50. Potential of rain screen walls to prevent rain penetration: pressurized cavity principle
  51. Quantitative driving rain exposure on a vertical wall at various Canadian cities
  52. Rapport Final Projet Site Internet - L'enveloppe du batiment et l'efficacit¨¦ ¨¦nerg¨¦tique
  53. Review and framework for large-scale laboratory studies on wetting and drying of building envelopes
  54. Study of the reduced impact of thermal bridges in two sprayed-applied polyurethane wall assemblies
  55. Study on thermal performance of curtain walls using infrared thermography
  56. Test method to measure the relative capacity of wall panels to evacuate moisture from their stud cavity
  57. Testing of flat roofs insulated with cellulose fiber
  58. The dynamic modelling of air humidity behaviour in a multi-zone space
  59. Transfer of heat, moisture and air through metal curtain walls
  60. Transient model for coupled heat, air and moisture transfer through multilayered porous media
  61. Use of an environmental chamber to investigate large-scale envelope specimen hygrothermal performance  



CRDBER, at CBS, BCEE, ENCS, Concordia,