The oven-dry method

"1. Scope

1.1 These test methods cover the determination of the moisture content ( MC ) of solid wood, veneer, and other wood-base materials, including those that contain adhesives and chemical additives. The test methods below describe primary (A) and secondary (B through D) procedures to measure moisture content:

2. Referenced Documents

D4933 Guide for Moisure Conditioning of Wood and Wood-Base Materials

D9 Termninology Relating to Wood"


Related Resources:
  • This link has not been checked.ASTM
    "provides a global forum for the development and publication of voluntary consensus standards for materials, products, systems, and services"

This publication in whole or part may be found online at: This link was checked on Dec. 2006here.

Related Concepts


Author Information and Other Publications Notes
ASTM
  1. ASTM C991-03 Standard Specification for Flexible Glass Fiber Insulation for Metal Buildings
  2. C1046-95, Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components
  3. C1060-90(1997)e1 Standard Practice for Thermographic Inspection of Insulation Installations in Envelope Cavities of Frame Buildings
  4. C1134-90(2001) Standard Test Method for Water Retention of Rigid Thermal Insulations Following Partial Immersion
  5. C1155-95, Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data
  6. C1193-00 Standard Guide for Use of Joint Sealants
  7. C1199-00 standard test method for measuring the steady-state thermal transmittance of fenestration systems using hot box methods
  8. C1363-97 standard test method for the thermal performance of building assemblies by means of a hot box apparatus
  9. C1498-01 standard test method for hygroscopic sorption isotherms of building materials
  10. C168-01 Standard Terminology Relating to Thermal Insulating Materials
  11. C177-85 Standard test method for steady-state heat flux measurements and thermal transmission properties by means of the guarded-hot-plate apparatus
  12. C209-98 standard test methods for cellulosic fiber insulating board
  13. C236-89, Standard test method for steady-state thermal performance of building assemblies by means of a guarded hot box
  14. C518-91, Standard test method for steady-state heat flux measurements and thermal transmission properties by means of the heat flow meter apparatus
  15. C755-85 Standard practice for selection of vapor retarders for thermal insulation
  16. C976-90(1996)e1 standard test method for thermal performance of building assemblies by means of a calibrated hot box
  17. D1413-76 Standard method of testing wood preservatives by laboratory soil block culture
  18. D3273-00 Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber
  19. D3274-95 Standard Test Method for Evaluating Degree of Surface Disfigurement of Paint Films by Microbial (Fungal or Algal) Growth or Soil and Dirt Accumulation
  20. D3679-02 Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Siding
  21. D4444-92e1 standard test methods for use and calibration of hand-held moisture meters
  22. D4933-99 Standard guide for moisture conditioning of wood and wood-base materials
  23. D6329-98 standard guide for developing methodology for evaluating the ability of indoor materials to support microbial growth using static environmental chambers
  24. E1105-00 Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform or Cyclic Static Air Pressure Difference
  25. E1186-98 Standard practices for air leakage site detection in building envelopes and air retarder systems
  26. E1258-88 Standard Test Method for Airflow Calibration of Fan Pressurization Devices
  27. E1424-91, Standard test method for determining the rate of air leakage through exterior windows, curtain walls, and doors under specified pressure and temperature differences across the specimen
  28. E1503-06 Standard Test Method for Conducting Outdoor Sound Measurements Using a Digital Statistical Sound Analysis System
  29. E1557-02 standard classification for building elements and related sitework-UNIFORMAT II
  30. E1646-95 Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference
  31. E1677-95(2000) standard specification for an air retarder (AR) material or system for low-rise framed building walls
  32. E1700-95(1999), standard classification for serviceability of an office facility for structure and building envelope
  33. E1825-96 Standard Guide for Evaluation of Exterior Building Wall Materials, Products, and Systems
  34. E1825-96, standard guide for evaluation of exterior building wall materials, products, and systems
  35. E1827-96 Standard Test Methods for Determining Airtightness of Buildings Using an Orifice Blower Door
  36. E1827-96(2002) Standard Test Methods for Determining Airtightness of Buildings Using an Orifice Blower Door
  37. E2099-00 standard practice for the specification and evaluation of pre-construction laboratory mockups of exterior wall systems
  38. E2099-00, standard practice for the specification and evaluation of pre-construction laboratory mockups of exterior wall systems
  39. E2128-01a Standard Guide for Evaluating Water Leakage of Building Walls
  40. E241-04 Standard Guide for Limiting Water-Induced Damage to Buildings
  41. E283-04, standard test method for rate of air leakage through exterior windows, curtain walls and doors
  42. E29-04 standard practice for using significant digits in test data to determine conformance with specifications
  43. E330-02 standard test method for structural performance of exterior windows, curtain walls, and doors by uniform static air pressure difference
  44. E331-00 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference
  45. E331-00, Standard test method for water penetration of exterior windows, curtain walls, and doors by uniform static air pressure difference
  46. E547-00: water penetration of exterior windows, curtain walls, and doors by cyclic static air pressure differential
  47. E631-93a(1998)e1 Standard Terminology of Building Constructions
  48. E632-82(1996) standard practice for developing accelerated tests to aid prediction of the service life of building components and materials
  49. E72-98 Standard Test Methods of Conducting Strength Tests of Panels for Building Construction
  50. E74-04 standard practice of calibration of force-measuring instruments for verifying the force indication of testing machines
  51. E741-00 Standard Test Method for Determining Air Change in a Single Zone by Means of a Tracer Gas Dilution
  52. E773-01, Standard test method for accelerated weathering of sealed insulating glass units
  53. E779-03, ASTM Method for Determining Air Leakage Rates by Fan Pressurization Test
  54. E779-99 Standard test method for determining air leakage rate by fan pressurization
  55. E783-02 standard test method for field measurement of air leakage through installed exterior windows and doors
  56. E917-99 standard practice for measuring life-cycle costs of buildings and building systems
  57. E964-93(1998)e1 Standard Practice for Measuring Benefit-to-Cost and Savings-to-Investment Ratios for Buildings and Building Systems
  58. E96-93 Standard test methods for water-vapor transmission of materials
  59. F1249-90(1995) Standard Test Method for Water Vapor Transmission Rate Through Plastic Film and Sheeting Using a Modulated Infrared Sensor
  60. F372-99 Standard Test Method for Water Vapor Transmission Rate of Flexible Barrier Materials Using an Infrared Detection Technique
  61. G84-89(1999)e1 standard practice for measurement of time-of-wetness on surfaces exposed to wetting conditions as in atmospheric corrosion testing
  62. Heat transmission measurements in thermal insulations
  63. Performance of exterior envelopes of whole buildings VIII: integration of building envelopes
  64. Standard guide for statistical evaluation of indoor air quality models. ASTM D 5157-97  