C1155-95, Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data

ASTM
2001
American Society for Testing and Materials, Philadelphia, Pa
calculation; heat flow; heat flux transducers; HFT; in-situ; mean temperature; measurement; thermal resistance


ASTM, (2001), "C1155-95, Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data", American Society for Testing and Materials, Philadelphia, Pa.
Abstract:
Scope:

1.1 This practice covers how to obtain and use data from in-situ measurement of temperatures and heat fluxes on building envelopes to compute thermal resistance. Thermal resistance is defined in Termninology C168 in terms of steady-state conditions only. This practice provides an estimate of that value for the range of temperatures encountered during the measurement of temperatures and heat flux.

1.2 This practice presents two specific techniques, the summation technique and the sum of least squares technique, and permits the use of other techniques that have been properly validated. This practice provides a means for estimating the mean temperature of the building component for estimating the dependence of measured R-value on temperature for the summation technique. The sum of least squares technique produces a calculation of thermal resistance which is a function of mean temperature.

1.3 Each thermal resistance calculation applies to a subsection of the building envelope component that was instrumented. Each calculation applies to temperature conditions similar to those of the measurement. The calculation of thermal resistance from in-situ data represents in-service conditions. However, field measurements of temperature and heat flux may not achieve the accuracy obtainable in laboratory apparatuses.

1.4 This practice permits calculation of thermal resistance on portions of a building envelope that have been properly instrumented with temperature and heat flux sensing instruments. The size of sensors and construction of the building component determine how many sensors shall be used and where they should be placed. Because of the variety of possible construction types, sensor placement and subsequent data analysis require the demonstrated good judgement of the user.

1.5 Each calculation pertains only to a defined subsection of the building envelope. Combining results from different subsections to characterize overall thermal resistance is beyond the scope of this practice.

1.6 This practice sets criteria for the data-collection techniques necessary for the calculation of thermal properties (see Note 1). Any valid technique may provide the data for this practice, but the results of this practice shall not be considered to be from an ASTM standard, unless the instrumentation technique itself is an ASTM standard.

Note 1--Currently only Practice C1046 can provide the data for this practice. It also offers guidance on how to place sensors in a manner representative of more than just the instrumented portions of the building components.

1.7 This practice pertains to light-through medium-weight construction as defined by example in . The calculations apply to the range of indoor and outdoor temperatures observed.

1.8 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


Related Resources:
  • This link has not been checked.ASTM
    "provides a global forum for the development and publication of voluntary consensus standards for materials, products, systems, and services"
  • This link has not been checked.DOE--Department of Energy
    "The Department of Energy's overarching mission is enhancing national security. Responsibility for accomplishing this mission is shared between four principal program lines."
  • ASTM Committee C16 on Thermal Insulation : Committee: C16.30

This publication in whole or part might be found online. Check the sources on the related article below. Or use search engines on the web.

Related Concepts


Author Information and Other Publications Notes
ASTM
  1. ASTM C991-03 Standard Specification for Flexible Glass Fiber Insulation for Metal Buildings
  2. C1046-95, Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components
  3. C1060-90(1997)e1 Standard Practice for Thermographic Inspection of Insulation Installations in Envelope Cavities of Frame Buildings
  4. C1134-90(2001) Standard Test Method for Water Retention of Rigid Thermal Insulations Following Partial Immersion
  5. C1193-00 Standard Guide for Use of Joint Sealants
  6. C1199-00 standard test method for measuring the steady-state thermal transmittance of fenestration systems using hot box methods
  7. C1363-97 standard test method for the thermal performance of building assemblies by means of a hot box apparatus
  8. C1498-01 standard test method for hygroscopic sorption isotherms of building materials
  9. C168-01 Standard Terminology Relating to Thermal Insulating Materials
  10. C177-85 Standard test method for steady-state heat flux measurements and thermal transmission properties by means of the guarded-hot-plate apparatus
  11. C209-98 standard test methods for cellulosic fiber insulating board
  12. C236-89, Standard test method for steady-state thermal performance of building assemblies by means of a guarded hot box
  13. C518-91, Standard test method for steady-state heat flux measurements and thermal transmission properties by means of the heat flow meter apparatus
  14. C755-85 Standard practice for selection of vapor retarders for thermal insulation
  15. C976-90(1996)e1 standard test method for thermal performance of building assemblies by means of a calibrated hot box
  16. D1413-76 Standard method of testing wood preservatives by laboratory soil block culture
  17. D3273-00 Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber
  18. D3274-95 Standard Test Method for Evaluating Degree of Surface Disfigurement of Paint Films by Microbial (Fungal or Algal) Growth or Soil and Dirt Accumulation
  19. D3679-02 Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Siding
  20. D4442-92(1997)e1 standard test methods for direct moisture content measurement of wood and wood-base materials
  21. D4444-92e1 standard test methods for use and calibration of hand-held moisture meters
  22. D4933-99 Standard guide for moisture conditioning of wood and wood-base materials
  23. D6329-98 standard guide for developing methodology for evaluating the ability of indoor materials to support microbial growth using static environmental chambers
  24. E1105-00 Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform or Cyclic Static Air Pressure Difference
  25. E1186-98 Standard practices for air leakage site detection in building envelopes and air retarder systems
  26. E1258-88 Standard Test Method for Airflow Calibration of Fan Pressurization Devices
  27. E1424-91, Standard test method for determining the rate of air leakage through exterior windows, curtain walls, and doors under specified pressure and temperature differences across the specimen
  28. E1503-06 Standard Test Method for Conducting Outdoor Sound Measurements Using a Digital Statistical Sound Analysis System
  29. E1557-02 standard classification for building elements and related sitework-UNIFORMAT II
  30. E1646-95 Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference
  31. E1677-95(2000) standard specification for an air retarder (AR) material or system for low-rise framed building walls
  32. E1700-95(1999), standard classification for serviceability of an office facility for structure and building envelope
  33. E1825-96 Standard Guide for Evaluation of Exterior Building Wall Materials, Products, and Systems
  34. E1825-96, standard guide for evaluation of exterior building wall materials, products, and systems
  35. E1827-96 Standard Test Methods for Determining Airtightness of Buildings Using an Orifice Blower Door
  36. E1827-96(2002) Standard Test Methods for Determining Airtightness of Buildings Using an Orifice Blower Door
  37. E2099-00 standard practice for the specification and evaluation of pre-construction laboratory mockups of exterior wall systems
  38. E2099-00, standard practice for the specification and evaluation of pre-construction laboratory mockups of exterior wall systems
  39. E2128-01a Standard Guide for Evaluating Water Leakage of Building Walls
  40. E241-04 Standard Guide for Limiting Water-Induced Damage to Buildings
  41. E283-04, standard test method for rate of air leakage through exterior windows, curtain walls and doors
  42. E29-04 standard practice for using significant digits in test data to determine conformance with specifications
  43. E330-02 standard test method for structural performance of exterior windows, curtain walls, and doors by uniform static air pressure difference
  44. E331-00 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference
  45. E331-00, Standard test method for water penetration of exterior windows, curtain walls, and doors by uniform static air pressure difference
  46. E547-00: water penetration of exterior windows, curtain walls, and doors by cyclic static air pressure differential
  47. E631-93a(1998)e1 Standard Terminology of Building Constructions
  48. E632-82(1996) standard practice for developing accelerated tests to aid prediction of the service life of building components and materials
  49. E72-98 Standard Test Methods of Conducting Strength Tests of Panels for Building Construction
  50. E74-04 standard practice of calibration of force-measuring instruments for verifying the force indication of testing machines
  51. E741-00 Standard Test Method for Determining Air Change in a Single Zone by Means of a Tracer Gas Dilution
  52. E773-01, Standard test method for accelerated weathering of sealed insulating glass units
  53. E779-03, ASTM Method for Determining Air Leakage Rates by Fan Pressurization Test
  54. E779-99 Standard test method for determining air leakage rate by fan pressurization
  55. E783-02 standard test method for field measurement of air leakage through installed exterior windows and doors
  56. E917-99 standard practice for measuring life-cycle costs of buildings and building systems
  57. E964-93(1998)e1 Standard Practice for Measuring Benefit-to-Cost and Savings-to-Investment Ratios for Buildings and Building Systems
  58. E96-93 Standard test methods for water-vapor transmission of materials
  59. F1249-90(1995) Standard Test Method for Water Vapor Transmission Rate Through Plastic Film and Sheeting Using a Modulated Infrared Sensor
  60. F372-99 Standard Test Method for Water Vapor Transmission Rate of Flexible Barrier Materials Using an Infrared Detection Technique
  61. G84-89(1999)e1 standard practice for measurement of time-of-wetness on surfaces exposed to wetting conditions as in atmospheric corrosion testing
  62. Heat transmission measurements in thermal insulations
  63. Performance of exterior envelopes of whole buildings VIII: integration of building envelopes
  64. Standard guide for statistical evaluation of indoor air quality models. ASTM D 5157-97  



CRDBER, at CBS, BCEE, ENCS, Concordia,